Securiton
Baldwin Boxall Network Expansion Panel Black 4 Way (C2CBNEP)

Network Expansion Panel Black 4 Way (C2CBNEP)

Control Panels

Brand
Baldwin Boxall
Model
Network Expansion Panel Black 4 Way (C2CBNEP)
Type
Control Panels
See all specifications

The Baldwin Boxall C2CFPE is a specialized Fire Panel & External Delayed Call Interface Module engineered for insertion into CARE2 master control consoles. It provides an opto-isolated link between the CARE2 Emergency Voice Communication (EVC) system and the building’s main Fire Alarm Control Panel (FACP), enabling automated system behavior during genuine fire events while supporting external alarm delays.

Fire Alarm System InterlockLinks directly to the FACP to manage disabled refuge outstations. It allows refuge outstations to remain in "Standby" mode during normal operations to eliminate nuisance/hoax calls, automatically activating them into full operation upon receiving a fire alarm trigger.
Selective Outstation OperationWhile disabled refuge outstations are held in standby, critical life-safety points—including Type A Fire Telephones, Roaming Telephone jacks, and Emergency Assistance Toilet Alarms—remain permanently active and monitored regardless of fire panel status.
External Delayed Call OutputFeatures an onboard potentiometer (VR1) and jumper configuration pins (P15/P16) to adjust and output an external delayed call signal. This allows activation of an external beacon or sounder (such as a BVOCCA lamp/buzzer) if an incoming call is not answered within a preset timeframe.
Configurable Relay OutputsProvides volt-free normally open (N/O) or normally closed (N/C) contacts, or direct switched +24 V DC outputs, to trigger third-party alarm indicators, sounders, or BMS systems. Plug-and-
Play Control Console FittingMounts directly inside the CARE2 control panel enclosure to the left of the main line cards and connects to the panel motherboard using a supplied yellow RJ45 link lead.
BS 5839-9 ComplianceFulfills UK standard recommendations for fire alarm system integration and anti-hoax call prevention on EVC networks.
View all

Baldwin Boxall

Console Black 4 Way (C2CB4)

Control Panels

  • Scalable 4-to-256 Way System: Begins as a compact 4-line unit, expands locally to 16 lines
  • Uninterrupted Power Protection: Built-in battery backup keeps the entire system fully operational
  • Clear Control & Accessibility: Combines an intuitive rotary encoder with a high-contrast LCD screen

Baldwin Boxall

4-Way Expansion Kit (C2CEK4)

Control Panels

  • Way Outstation Line Capacity: Supplied as a 4-way base panel
  • Network Expansion & Scalability: Supports up to 15 Network Expansion Panels (NEPs)
  • Network Ring Topology: Interconnects control panels

Baldwin Boxall

Fire Panel/Ethernet Module (C2CFPE)

Control Panels

  • Ethernet & PC Configuration: Features an onboard Ethernet port to allow remote programming
  • Flexible Fire Panel Inputs: Supports both volt-free contact inputs
  • Common Fault Relay Outputs: Provides dedicated fault contacts to relay CARE2 system status

Baldwin Boxall

Network Card (C2CN)

Control Panels

  • Panel Network Interconnect: Enables ring networking for up to 16 panels
  • Included Modular Kit: Supplied complete with the C2CN PCB card
  • BVOCCA & Delayed Call Control: Includes jumper configuration settings

Baldwin Boxall

Fire Telephone Lock door Red (C2FTRL)

Devices

  • BS 5839-9 Type A Life Safety: Fully certified Type A emergency outstation designed
  • Powered Operation: Powered directly over a 2-core radial connection
  • Distance Radial Cabling: Supports cable distances up to 500 meters between the control panel

Baldwin Boxall

Fire Telephone Push door Red (C2FTRP)

Devices

  • Safety Compliance: Certified Type A outstation engineered to support emergency personnel
  • Duplex Speech & Conference Capability: Enables simultaneous two-way audio back to the central console
  • Hearing Aid Accessible Handset: Fitted with a high-durability red handset

Baldwin Boxall

3 Part Disable Toilet Alarm Kit -White (DTAKIT)

Devices

  • Part Alarm Package: Supplied with a ceiling pull cord unit, a reset point switch
  • Universal EVC System Compatibility: Connects directly into CARE2, OmniCare, and OmniCarePLUS EVC networks
  • Interactive Caller Reassurance: Accepting an active call at the master control panel sends visual

Baldwin Boxall

4 Way Toilet Alarm Control Panel White (DTA4)

Control Panels

  • Chain Expansion: Directly controls up to 4 assistance alarm zones
  • Interactive Call Acknowledge & Reassurance: Pressing a zone's call accept button on the panel alters the visual
  • Continuous Line & Fault Surveillance: Continuously monitors field wiring for open or short circuit faults

Baldwin Boxall

Call Button White (DTACB)

Devices

  • Safety Compliance: Designed to fulfill UK building accessibility standards
  • Backed: Powered directly from the host EVC panel or DTA4 controller line
  • Way Call Acknowledge & Reassurance: Accepting an active call at the control panel changes the visual

Baldwin Boxall

Call Button & Reset Point White (DTACBRP)

Devices

  • Combined Call & Reset Functionality: Integrates a prominent emergency call push-button
  • Interactive Caller Reassurance: Features internal LED indicators
  • Powered Operation: Powered directly over the system loop or radial line (16–20 V DC)

Specification and budget estimate

Tell us about the building and we will come back with a specification and a budget estimate for the Baldwin Boxall Network Expansion Panel Black 4 Way (C2CBNEP).