The Baldwin Boxall CARE2 Type A Fire Telephone Outstation (Model C2FTRL / C2FTRP / C2FTSL / C2FTSP) is a heavy-duty emergency telephone outstation designed for fire officers and building control during emergency evacuations. Housed in a durable enclosure with door-latch call activation, it provides full-duplex, two-way speech communication back to the main console and runs entirely on line power provided over a 2-core radial cable run.

BS 5839-9 Type A Life SafetyFully certified Type A emergency outstation designed for emergency services and building evacuation teams. Line-
Powered OperationPowered directly over a 2-core radial connection (16–20 V DC) from the main panel, utilizing the central unit's 24-hour battery backup system. Long-
Distance Radial CablingSupports cable distances up to 500 meters between the control panel and individual outstations using enhanced 2-core fire-rated cable.
Hearing Aid Compatible HandsetEquipped with a rugged red telephone handset featuring a high-volume ringer and an integrated T-coil earpiece for hearing aid accessibility. Door-
Activated Call TriggerOpening the enclosure door automatically initiates an emergency call to the control console.
Flexible Enclosure & Finish OptionsAvailable in Red or Stainless Steel finishes, with a choice of Push Door or Slot Lock access, for surface mounting or flush mounting using dedicated bezels (C2FTRZ / C2FTSZ).
View all

Baldwin Boxall

Console Black 4 Way (C2CB4)

Control Panels

  • Scalable 4-to-256 Way System: Begins as a compact 4-line unit, expands locally to 16 lines
  • Uninterrupted Power Protection: Built-in battery backup keeps the entire system fully operational
  • Clear Control & Accessibility: Combines an intuitive rotary encoder with a high-contrast LCD screen

Baldwin Boxall

4-Way Expansion Kit (C2CEK4)

Control Panels

  • Way Outstation Line Capacity: Supplied as a 4-way base panel
  • Network Expansion & Scalability: Supports up to 15 Network Expansion Panels (NEPs)
  • Network Ring Topology: Interconnects control panels

Baldwin Boxall

Fire Panel/Ethernet Module (C2CFPE)

Control Panels

  • Ethernet & PC Configuration: Features an onboard Ethernet port to allow remote programming
  • Flexible Fire Panel Inputs: Supports both volt-free contact inputs
  • Common Fault Relay Outputs: Provides dedicated fault contacts to relay CARE2 system status

Baldwin Boxall

Network Card (C2CN)

Control Panels

  • Panel Network Interconnect: Enables ring networking for up to 16 panels
  • Included Modular Kit: Supplied complete with the C2CN PCB card
  • BVOCCA & Delayed Call Control: Includes jumper configuration settings

Baldwin Boxall

Network Expansion Panel Black 4 Way (C2CBNEP)

Control Panels

  • Fire Alarm System Interlock: Links directly to the FACP to manage disabled refuge outstations
  • Selective Outstation Operation: While disabled refuge outstations are held in standby
  • External Delayed Call Output: Features an onboard potentiometer (VR1) and jumper configuration pins

Baldwin Boxall

Fire Telephone Push door Red (C2FTRP)

Devices

  • Safety Compliance: Certified Type A outstation engineered to support emergency personnel
  • Duplex Speech & Conference Capability: Enables simultaneous two-way audio back to the central console
  • Hearing Aid Accessible Handset: Fitted with a high-durability red handset

Baldwin Boxall

3 Part Disable Toilet Alarm Kit -White (DTAKIT)

Devices

  • Part Alarm Package: Supplied with a ceiling pull cord unit, a reset point switch
  • Universal EVC System Compatibility: Connects directly into CARE2, OmniCare, and OmniCarePLUS EVC networks
  • Interactive Caller Reassurance: Accepting an active call at the master control panel sends visual

Baldwin Boxall

4 Way Toilet Alarm Control Panel White (DTA4)

Control Panels

  • Chain Expansion: Directly controls up to 4 assistance alarm zones
  • Interactive Call Acknowledge & Reassurance: Pressing a zone's call accept button on the panel alters the visual
  • Continuous Line & Fault Surveillance: Continuously monitors field wiring for open or short circuit faults

Baldwin Boxall

Call Button White (DTACB)

Devices

  • Safety Compliance: Designed to fulfill UK building accessibility standards
  • Backed: Powered directly from the host EVC panel or DTA4 controller line
  • Way Call Acknowledge & Reassurance: Accepting an active call at the control panel changes the visual

Baldwin Boxall

Call Button & Reset Point White (DTACBRP)

Devices

  • Combined Call & Reset Functionality: Integrates a prominent emergency call push-button
  • Interactive Caller Reassurance: Features internal LED indicators
  • Powered Operation: Powered directly over the system loop or radial line (16–20 V DC)